Materials and Methods: The split renal function (SRF) percentage of living kidney donor candidates was determined by diethylenetriamine pentaacetic acid (DTPA) perfusion scintigraphy. The modified ellipsoid volume (MELV), semi-automatic total kidney volume (STKV) and semi-automatic renal cortex volume (SRCV) of the candidates who underwent contrast-enhanced CT were measured and the percentages of both kidney volumes were calculated. The inter-method agreement was evaluated using Pearson's correlation test and the Bland-Altman plot test.
Results: There was no correlation between the right and left kidney SRF and MELV (r=-0.033 and r=-0.092), MELV% (r=0.076 and r=0.076), STKV (r=-0.005 and r=-0.120), STKV% (r=0.175 and r=0.172), SRCV (r=-0.001 and r=0.130) and SRCV% (r=0.205 and r=0.183). There were significant correlations between the right MELV and STKV (r=0.855) and SRCV (r=0.813), and between the left MELV and STKV (r=0.787) and SRCV (r=0.770).
Conclusion: Although CT provided detailed preoperative anatomical information, volumetric measurements did not show agreement with SRF. The agreement of each 3 volumetric examinations within themselves made us think that disagreement with SRF was independent of the volumetric method chosen.